LUMA-6CH / Safety
Safety Information
Read before installing, wiring, configuring or servicing LUMA-6CH. Retain these instructions with the installation records.
Last updated: 24 August 2026
Electrical and fire hazard
Disconnect power and verify absence of voltage before work. Incorrect wiring, undersized conductors, inadequate protection or exceeding ratings may cause overheating, fire or damage.
1 / Qualified installation
- Permanent installation in a panel or building system must be carried out by qualified personnel under local rules.
- Install in a protected enclosure suitable for the environment, on a DIN rail or with the intended mounting method.
- The device is not an isolating switch. Provide an accessible means to disconnect its supply.
2 / Power and loads
- Use only a regulated 12–24 V DC supply sized for load, inrush and wiring.
- Observe polarity, wiring diagram and terminal markings for the specific unit.
- Do not exceed 180 W on any channel or 500 W combined.
- Size conductors, terminals, fuses and overcurrent protection for actual current and voltage drop.
- D1 and D2 data outputs are not power outputs.
3 / Environment and cooling
- Use in a dry location protected from water, condensation, conductive dust and corrosive or explosive atmospheres.
- Provide adequate space and ventilation. Do not cover the device or install it next to heat sources.
- Do not use if the enclosure, terminals or wiring are damaged, deformed, discoloured or excessively hot.
4 / Operation and servicing
- Do not open or modify the device. It contains no user-serviceable parts.
- Do not rely on LUMA for safety, emergency, evacuation or life-protection functions without compliant independent systems.
- Ensure stable power before firmware updates. Install only authentic OBJEX LABS releases.
- After any change, verify manual operation, scenes, automations and behaviour without network connectivity.
5 / If something is wrong
Immediately disconnect power if there is odour, smoke, unusual noise, overheating, liquid ingress or damage. Do not re-energize until qualified personnel have inspected the system.
Support: info@objexlabs.com.